This page lists what a basement room must have before it can be called a bedroom in West Jordan. A licensed contractor handles the building. West Jordan Basement Finishing's part is the referral: passing your request to a licensed local contractor. You handle the decisions and the questions.
What the plans call a room does not settle it. The code requires at least one operable escape opening in every basement and, where a basement contains sleeping rooms, one in each of them, so a basement room people will sleep in needs its own escape opening (UpCodes' third-party copy of the code). The five requirements for a basement bedroom are below.
The five-point checklist
1. An emergency escape opening in that room
Utah's adopted IRC requires an operable emergency escape and rescue opening in each basement bedroom (UpCodes' third-party copy of the code). The sizes, the sill height and the well outside are on the egress window page. Utah's amendment to R310.7 says a new bedroom or accessory dwelling unit created in an existing basement needs one.
2. A ceiling high enough
The IRC calls for at least 7 feet of ceiling height in habitable space, and the city's Basement Finish Guide asks for a 7 foot minimum with surface-mount lighting and other projections not encroaching into it. The IRC lets beams, girders and ducts project to within 6 feet 4 inches of the finished floor, while the city's guide says projections must not encroach, so ask the plans examiner at 801-569-5050 which applies. Measure before you draw the room, because a bulkhead over the bed can decide the layout.
3. Smoke alarms in the right places
The city's guide asks for battery-backed, interconnected 120-volt smoke detectors in every bedroom and in the hallways leading to the bedrooms. The IRC adds that alarms must be interconnected so one sets off all of them, and it allows listed wireless interconnection (UpCodes' third-party copy of the code), but West Jordan's guide still calls for 120-volt, battery-backed detectors. Utah's amendment also says that when alterations, repairs, accessory dwelling units or additions needing a permit are done, the whole dwelling unit gets smoke alarms placed as for a new home. That means the finish can pull the upstairs alarms into the job.
4. Carbon monoxide alarms
The city's guide asks for one carbon monoxide detector, or a combination smoke/CO detector, per floor. Utah's amended IRC goes by each level and outside each sleeping area. Ask the contractor to mark both on the plan, and ask Building & Safety at 801-569-5050 which one the city reviews against.
5. A permit that shows it
The bedroom belongs on the plans submitted to the city, with the room labeled and the window shown, so the plans examiner can check it. See the West Jordan permit page.
Details the plans examiner settles
- A closet. Ask the plans examiner whether the room needs one to be labeled a bedroom. A room people will sleep in needs its own escape opening either way.
- A minimum floor area. Same answer: the city decides.
- "It was fine for the last owner." Utah's added R102.7.2 protects an existing bedroom in a narrow case, as the egress page explains. It does not make a new room legal.
Do not skip the finish permit
The city's accessory dwelling unit checklist includes a line to verify that a building permit was obtained to finish the basement; confirm with Building & Safety at 801-569-5050, because rules change. If you may ever want a rental unit, the paper trail starts with this permit. See the basement apartment page.
Checklist before you ask for a match
- How many bedrooms and their rough sizes.
- The wall each one would use for a window.
- A radon test result, or a plan to test. The EPA says to test before you begin a remodel, and to fix a home at 4 pCi/L or more.
- Any signs of moisture on the walls you want to use.
Questions for the contractor
- Which rooms on your drawing are labeled bedrooms?
- What window and well serve each one?
- Where do the smoke and CO alarms go?
- How low does the ceiling get under the ducts?
- Who pulls the permit?
Common questions
Can a basement bedroom be rented?
Utah law lets a city prohibit renting an internal accessory dwelling unit for less than 30 consecutive days. A single rented room is a different question for the city.
Do the rules apply if a previous owner finished a bedroom years ago?
Utah's added R102.7.2 protects an existing bedroom whose egress window met the code in force when it was finished, but only in the narrow case the egress page describes. Ask Building & Safety at 801-569-5050 what applies to yours.
Rules and fees change, so check with West Jordan Building & Safety at 801-569-5050 before you commit. To be matched with a contractor, call (385) 255-7293 or send the form.
Where these rules come from
The ceiling and alarm items are from West Jordan's Basement Finish Guide, the carbon monoxide amendment and the rental rule from the linked Utah Code pages, the R102.7.2 rule for existing bedrooms from Utah Code 15A-3-202, and the other state items from UpCodes' third-party copy of the Utah-amended IRC, read in November 2026.